Feature |
Description |
Remark |
Full collective selective |
In automatic running or attendant state,
this function enables the elevator to respond both car calls and hall
calls.
Passengers at any service floor can call the elevator by pressing
the up call button and down call button. |
● |
Anti-nuisance function |
The system automatically judges the number
of passengers in the car and compares it with the number of registered
car calls.
If there are excessive car calls, the system determines that it is
nuisance and cancels all car calls. In this case, passengers need
to register correct car calls again. |
● |
Car Call Cancellation |
Passengers can press the button consecutively
twice to cancel wrong calls. |
● |
Turn Off of Car Light
and Fan |
If there is no running command within
the set time, the system automatically cuts off the power supply to
the lamp and fan in the car. |
● |
Full-load direct runnung |
When the car is full-loaded in automatic
running state, the elevator does not respond to hall calls from the
passing floors. These halls calls, however,
can still be registered, and will be executed at next time of running
(in the case of single elevator) or by another elevator
(in the case of parallel/group control). |
● |
Overload protection |
When the car load exceeds the rated elevator
load, the elevator alarms and stops running. |
● |
Button stuck check |
The system can automatically identify
whether a hall call button is stuck and cancel the stuck call,
preventing the condition that the elevator cannot close and run due
to stuck hall calls. |
● |
Repeat door close |
If the door lock is not applied after
the elevator performs door close for a certain time, the elevator
automatically opens the door and then closes the
door again. |
● |
Automatic door open upon door
lock abnormality |
If the system detects that the door lock
circuit is abnormal during door open/close, the elevator automatically
opens and closes the door again,
and reports a fault after the set door open/close times is reached. |
● |
Door open time setting |
The system automatically determines different
door open time for door open for call, command, protection,
or delay according to the set door open holding time. |
● |
Arrival gong disabled at night |
Within the set time period, the arrival
gong is disabled. |
● |
Landing at another floor |
If the door open time exceeds the door
open protection time but the door open limit signal is still inactive,
the elevator closes the door and then automatically runs to the next
landing floor. |
● |
Voice Announcement |
The elevator automatically announces information
such as the running direction and next arriving floor
during running. |
● |
Forced door close |
When the door fails to close within the
set time due to the action of the light curtain or safety edge, the
elevator enters the forced door close state,
closes the door slowly, and gives a prompt tone. |
● |
Group control |
The system supports parallel control of
two elevators / group control of more than three elevators |
○ |
Micro Leveling |
After landing at a floor, the elevator
may move upward or downward due to the load change and the car door
is not aligned with the ground,
which is inconvenient for in and out of passengers and goods. In this
case, the system allows the elevator to run to the leveling position
in the door
open state at the leveling speed. |
○ |
Light curtain signal judgment |
If the door is blocked by stuff during
door close, the light curtain acts and the elevator opens the door.
This function is invalid in fire emergency state. |
○ |
Power failure emergency
evacuation |
For the elevator configured with standby
power supply, the system uses the standby power supply (ARD System)
to implement low-speed self-rescue
in the case of power failure. |
○ |
Residential monitoring |
The control system can be connected to
the terminal in the monitoring room. By using the NEMS software,
you can view the floor position, running direction, and fault state
of the elevator. |
○ |
Parking Operation |
In order for park the elevator, if the
parking key is on position the car stop at the specified floor after
finish servicing of all of registered call.
After the car stops at the specified floor, the car light and fan
are off automatically and every buttons both on the car operating
panel and
hall button box are no more available. |
○ |
Fire return Operation |
In case of fire every cars should be returned
to the specified floor in order to evacuate passengers safety. |
○ |
Fireman Operation |
In case of fire, a fireman can use the
elevator which is stopped at the specified floor in order to support
fireman for fire-fighting. |
○ |